Use of the Modified Cup Method to Determine Temperature Dependency of Water Vapor Transmission Properties of Building Materials
ASTM International

Books & Journals/Journal of Testing and Evaluation/Citation Page/

Volume 33, Issue 5 (September 2005)

ISSN: 0090-3973
Published Online: 10 August 2005
Page Count: 7

Click here to download this paper now

View License Agreement

Use of the Modified Cup Method to Determine Temperature Dependency of Water Vapor Transmission Properties of Building Materials
Mukhopadhyaya, P
Research Officer, National Research Council, Ottawa, Ontario, Canada.

Kumaran, MK
Principal Research Officer, National Research Council, Ottawa, Ontario, Canada.

Lackey, J
Technical Officer, National Research Council, Ottawa, Ontario, Canada.

(Received 5 January 2004; accepted 10 January 2005)

Abstract
This paper describes a modified cup method and its application to investigate the effects of temperature on the water vapor transmission (WVT) properties of building materials. The modified cup method is a simple and versatile technique that allows the user to vary the temperature condition of the test without altering the relative humidity. Two commonly used building materials considered in this study were fiberboard and gypsum board. The five temperature levels under consideration were between 7°C and 43°C. The WVT properties were measured at 50 % average relative humidity. The results obtained from these tests are critically analyzed and reported in this paper. These results demonstrate that there is a steady exponential increase of WVT rate, through both the materials tested, with temperature. However, water vapor permeability (WVP) through the materials shows no significant change due to the variation of temperature between 7 and 43°C. The general observations made in this study confirm that the modified cup method could be used reliably to measure WVT properties of building materials. Detailed analysis of the test results also reaffirms the fact that, for fiberboard and gypsum board, at 50 % average relative humidity condition, the WVP is not dependent on the temperature condition.

Keywords:
modified cup method, temperature dependency, water vapor permeability, water vapor transmission

Paper ID: JTE12507
DOI: 10.1520/JTE12507

ASTM International is a member of CrossRef.
Author Mukhopadhyaya, P Affiliation Research Officer, National Research Council, Ottawa, Ontario, Canada. Author Kumaran, MK Affiliation Principal Research Officer, National Research Council, Ottawa, Ontario, Canada. Author Lackey, J Affiliation Technical Officer, National Research Council, Ottawa, Ontario, Canada. Author Mukhopadhyaya P, Kumaran MK, Lackey J Title Use of the Modified Cup Method to Determine Temperature Dependency of Water Vapor Transmission Properties of Building Materials Symposium , Committee on

 
Copyright © 1996-2006 ASTM. All Rights Reserved.