Comparison of Laboratory-Measured GCL Hydraulic Conductivity Based on Three Permeameter Types
Petrov RJ, Rowe RK, Quigley RM
(Received 2 January 1996; accepted 5 August 1996)

Abstract
Specimen preparation, installation, and testing procedures are presented for testing a needle-punched geosynthetic clay liner (GCL) in a consolidation-type, fixed-ring constant-flow-rate hydraulic conductivity apparatus. The proposed approach is illustrated by reporting the results obtained for a GCL statically confined to effective stresses of ~3 and ~35 kPa, hydrated and permeated with distilled water and concentrated aqueous salt solutions (0.6 and 2.0 N NaCl), and sequentially permeated with concentrated aqueous salt solutions (0.6 and 2.0 N NaCl) after initial permeation with distilled water. The issue of potential preferential sidewall flow in the fixed-ring permeameter tests was then addressed by comparing results with those conducted under otherwise similar testing conditions in a double-ring and flexible-wall permeameter. Reasonable reproducibility of the test results was obtained between the different types of permeameters, suggesting that, if present, preferential sidewall flow was negligibly small and was not significant on the calculated hydraulic conductivity values. This conclusion was found to be valid for the range of permeant types (distilled water and 0.6 and 2.0 N NaCl), static-confining stresses, and hydrating mediums considered. Premature arrival of the salt solution front in the effluent (i.e., solute breakthrough) during fixed-ring hydraulic conductivity testing was explained as a probable diffusion-dominated transport mechanism through the relatively thin GCL specimens.

Keywords:
bentonite, compatibility, diffusion, double-ring permeameter, fixed-ring permeameter, flexible-wall permeameter, geosynthetic clay liner (GCL), hydraulic conductivity

ASTM International is a member of CrossRef.
Author Petrov RJ, Rowe RK, Quigley RM Title Comparison of Laboratory-Measured GCL Hydraulic Conductivity Based on Three Permeameter Types Symposium , Committee on

 
Copyright © 1996-2007 ASTM. All Rights Reserved.
ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA, 19428-2959 USA