Water Pressure Measurement with Time Domain Reflectometry Cables
ASTM International

Books & Journals/Geotechnical Testing Journal/Citation Page/

Volume 19, Issue 1 (March 1996)

ISSN: 0149-6115
Published Online: 0 0
Page Count: 7

PDF not available for download

View License Agreement

Water Pressure Measurement with Time Domain Reflectometry Cables
Dowding CH, Huang F, McComb PS
(Received 0 0; accepted 0 0)

Abstract
Attributes of the remote measurement of piezometric water pressure and water level with time domain reflectometry (TDR) techniques are investigated. The evaluation includes a two-wire system for unusually small riser tubes as well as parallel wire and air-filled or hollow coaxial cable for typical installations. Comparison of TDR cable and commercial pressure transducer technology shows coaxial cable TDR systems with distance crimps capable of equaling and exceeding the resolution of pressure transducers. Crimps provide permanent distance markers that allow the TDR system to be self-calibrating.

Keywords:
air-water interface, coaxial cable, multiplexing, piezometer, pressure transducer, remote operation, telemetry, time domain reflectometry, water pressure

ASTM International is a member of CrossRef.
Author Dowding CH, Huang F, McComb PS Title Water Pressure Measurement with Time Domain Reflectometry Cables Symposium , Committee on

 
Copyright © 1996-2007 ASTM. All Rights Reserved.
ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA, 19428-2959 USA